New FW UPDATE For ICOM 9700 – 705 AND 7300

  • 705:
Changes from Version 1.24 – When in the Center mode of the Spectrum scope screen, the REF level setting does not reflect the scope waveform during transmission. – This firmware update version 1.26 has been improved, so it will not reset settings and memories. If the firmware is updated from version 1.24 or earlier, the settings and memories are not reset.  However, if the firmware is reverted to 1.26 from a later version (after 1.26), the settings and memories may be reset.
NOTE:You cannot revert to firmware version 1.24 or earlier on the serial numbers listed below, which have firmware version 1.26 or later installed. IC-705    #32: Serial number 32001001 or later
IC-705    #33: Serial number 33001001 or later
IC-705-T  #36: Serial number 36001001 or later
IC-705    #37: Serial number 37001001 or later Please note on the models listed above, if you revert to firmware version 1.24 or earlier, the audio will not be correctly output.

https://www.icomjapan.com/support/firmware_driver/3343/?fbclid=IwAR2PJfKott-N3C_UiRt7oMMbd3SDVJ4RbsLGYsE05TUbxUD7QDPuqkxxBYk

  • 9700:

Changes from Version 1.30


– When in the Center mode of the Spectrum scope screen, the REF level setting does not reflect the scope waveform during transmission.


– This firmware update version 1.31 has been improved, so it will not reset settings and memories.
If the firmware is updated from version 1.30 or earlier, the settings and memories are not reset.
However, if the firmware is reverted to 1.31 from a later version (after 1.31), the settings and memories may be reset.


– Improved the transceiver to not display a thick white line indicating the center when in the Center mode of the Spectrum scope screen.

https://www.icomjapan.com/support/firmware_driver/3338/

  • 7300:

Changes from Version 1.40

  • – Added the set item to detect the Microphone PTT operation during transmission other than the Microphone PTT operation. 
  • – When in the Center mode of the Spectrum scope screen, the REF level setting does not reflect the scope waveform during transmission.
  • – This firmware update version 1.41 has been improved, so it will not reset settings and memories.
  • If the firmware is updated from version 1.40 or earlier, the settings and memories are not reset. 
  • However, if the firmware is reverted to 1.41 from a later version (after 1.41), the settings and memories may be reset.

https://www.icomjapan.com/support/firmware_driver/3339/?fbclid=IwAR2hzR86KXWNCU1YhArAUtyjmbugWkReKZl53O6trsUrBzUTjx9SgSp-y-k

Visitas: 52

Por EA7IYR

Deja una respuesta